No light

 

On the old-fashioned Q drive, the three gears of ON, OFF, and RUN have been selected incorrectly. OFF is the command to force the laser to be turned off, and ON is the command to force the light emission. The correct method is to select RUN to run.

The board card is broken, replace the board card. The voltage of the Q signal on the board. Under normal circumstances, the voltage of the Q signal is: low level for the Kairui board, that is, 0V when marking, 5V when not marking; high when marking the golden orange board The level is 5V when marking, and 0V when not marking.

The signal connection between the board and the driver is open. Replace or re-solder.

The light path is not adjusted properly, re-adjust the light path.

If the krypton lamp is broken, replace the krypton lamp.

Computer operating system or computer obstruction, reinstall the system or exchange the computer.

The laser power supply is broken. Replace the laser power supply.

Q driver is broken, replace Q driver.

Q switch is broken, replace Q switch.

 

 

Weak light

 

Marking software CW method is not selected, the light will be very weak, select CW method.

The M1, M2, and M3 gears on the Q drive are dialed incorrectly. The correct way is to select M1.

The focal length is wrong, adjust the focal length again.

The water temperature is too high.

The krypton lamp is aging, replace the krypton lamp.

The lenses of the total or semi-reflective lens, focusing lens, galvanometer lens, and Q switch are dirty or scratched. Wipe clean or exchange.

The cavity, total reflector, half reflector and beam expander are not adjusted properly. Re-adjust.

The Q switch is not adjusted properly. Normally, it emits light when marking. When not marking, the Q switch must lock the laser. The current of the laser power supply can be adjusted to a higher value, and the frequency doubler is placed in front of the half mirror to see if there is any light leakage. If the light leaks, the light will be very weak, re-adjust the Q switch.

The laser did not hit the center of the galvanometer, or the lens of the galvanometer was scratched. Re-adjust the light path, or change the galvanometer.

 

Continuous light

 

Wrong switching sequence may cause continuous light emission. The correct boot sequence is: total power supply => computer => marking software => chiller => Q drive => laser power supply => after the READY light on the isostimulus power supply is on => press the RUN key to start => galvanometer power switch . The shutdown sequence is reversed.

The ON, OFF, and RUN gear switches on the old-fashioned Q drive are dialed incorrectly. ON is a forced light-emitting command, and OFF is a forced laser-off command. The correct method is to select RUN to run.

The board card is broken, replace the board card. For Kairui boards, pay attention to the jumper cap on the board: YAG50 jumper cap should jump to the T end. (Be sure to pay attention to this problem when replacing the Kairui board)

The Q switch is not adjusted properly. Normally, it emits light when marking. When not marking, the Q switch must lock the laser.

In the case of Kairui Software, it may be relocated because of a problem with the marking software.

Computer or operating system problems. Exchange or reinstall the system.

Q driver is broken, replace Q driver.

If the Q switch is broken, replace the Q switch (this kind of situation is rare, generally speaking, if the Q switch is broken, the Q driver will alarm)

 

The galvanometer does not move

 

The parameter X, Y ratio adjustment option on the Kairui software is zero, the galvanometer will not move, and the parameters will be adjusted again.

The board card is broken, replace the board card. The voltage of the X and Y galvanometer signals on the board is normal: it changes between 0-5V when marking, and it is 0V when not marking.

The galvanometer signal line is open circuit, exchange it.

For Qin Long's galvanometer, the jumper cap next to the signal indicator on the driver must be removed, otherwise the galvanometer will not move.

The galvanometer is obstructed, change the galvanometer.

Computer operating system or computer obstruction, reinstall the system or exchange the computer.

 

Galvanometer jitter and howling

 

The ground wire is not connected properly, reconnect the ground wire.

The board card is broken, replace the board card.

Turn off the laser power supply and Q drive, and gently touch the galvanometer lens to see if the galvanometer is shaking or hear whether the galvanometer is squeaking. If the obstruction is eliminated, turn on the laser power supply and Q drive one by one to determine whether it is caused by the laser power supply or the Q drive.

If the galvanometer jitter or howling is caused by the laser power supply, the high-voltage line of the laser power supply can be separated from other signal lines as much as possible. Generally speaking, the obstruction can be eliminated. If the obstruction still exists, switch the laser power supply.

If the galvanometer jitter or howling is caused by the Q driver, you should check whether the connection between the Q driver and the Q switch is short-circuited. The signal line short-circuit will cause this obstruction. If the obstruction still exists, replace the Q drive.

The galvanometer is broken, replace the galvanometer.

Computer operating system or computer obstruction, reinstall the system or exchange the computer.

 

Marking effect is not good

 

(YMDF and RF series marking machines have the same processing methods)

Причина маркировки программного обеспечения или системы. Переустановите систему или программное обеспечение для маркировки.

Параметры программного обеспечения для маркировки настроены неправильно. Повторно настройте параметры.

Фокус отрегулирован неправильно, отрегулируйте фокус еще раз.

Размеченная графика выполнена некачественно или материал для маркировки недоступен.

 

Графическое искажение

 

(маркировочные машины серии YMDF и RF имеют одинаковые методы обработки)

Графика сама по себе не очень, переделывай.

Параметры не отрегулированы должным образом, повторно отрегулируйте выпуклость подушечки для иголок и коррекцию горизонтальной прямолинейности в коррекции искажения.

Гальванометр не отрегулирован должным образом. Исправление.

Возникла проблема с программным обеспечением или системой маркировки. Переместите программное обеспечение или систему маркировки.

Гальванометр сломан, замените гальванометр.

 

Не тот размер

 

(маркировочные машины серии YMDF и RF имеют одинаковые методы обработки)

Размер экспортируемого графика не соответствует требуемому размеру графика, переделайте график. Простая графика может быть обновлена ​​в размере с помощью программного обеспечения для маркировки, а графика с двойным смешением легко деформируется.

Фокусное расстояние было преобразовано, и фокусное расстояние было перенастроено.

Пропорциональный параметр настроен неправильно. Повторно настройте параметры.

Если на одном и том же графике отмечено несколько шаблонов, размер каждого шаблона разный, программное обеспечение Golden Orange может настроить параметры коррекции. Kairui Software не имеет возможности настройки этого параметра.

 

Несоосность маркировки

 

После работы в течение определенного периода времени маркировка смещается (маркировочные машины серии YMDF и RF имеют одинаковые методы обработки)

Винт для стабилизации гальванометра не затянут, поэтому стабилизируйте гальванометр плотно.

Иногда эту проблему могут вызывать проблемы с операционной системой или маркировкой программного обеспечения, или операционная система с антивирусным программным обеспечением. Переустановите систему или удалите антивирусное программное обеспечение и переустановите программное обеспечение для маркировки.

Если у вас проблемы с гальванометром, замените гальванометр.

 

Разметьте прямые линии в волны

 

Маркировка прямой линии в форме волны (методы обработки маркировочной машины серии YMDF, RF одинаковы)

Заземляющий провод подсоединен не плохо, а заземляющий провод повторно заземлен.

Проблема с гальванометром, поменяй гальванометр,

Блок питания лазера, статическое электричество и прочие неприятности.

 

Ножной переключатель не работает

 

Ножной переключатель не работает (методы обработки маркировочных машин серии YMDF, RF одинаковы)

Если вы используете ножной переключатель программного обеспечения Kairui, вы должны использовать маленькую треугольную отметку на общей панели инструментов программного обеспечения для маркировки (нажмите F5, чтобы открыть это диалоговое окно маркировки). Если вы нажмете кнопку маркировки в строке состояния, чтобы отметить, ножной переключатель не работает.

ультрафиолетовый лазер  | зеленый лазер  | ультрафиолетовые лазеры  | ультрафиолетовый лазер dpss  | наносекундный лазер  | УФ лазерный источник  | Твердотельные лазеры

Ножной переключатель сломан, замените ножной переключатель.

 

Доска сломана. Напряжение сигнала ножного переключателя. Обычно напряжение сигнала составляет 5 В как для маркировки, так и для немаркировки.

Сигнальное соединение между платой и педальным переключателем разомкнуто.

Если это плата золотисто-оранжевого цвета, также проверьте, равно ли значение параметра (параметр F3)/порта/начального порта маркировки/входного порта 0, если оно не установлено на 0, ножной переключатель не будет работать.

 

Сработал воздушный выключатель

 

Проверьте, нет ли где-нибудь воспламенения высокого давления.

Проверьте, превышает ли выходная мощность номинальную мощность

Компоненты главной цепи повреждены

 

Чиллер не работает

 

Подключен ли шнур питания чиллера

Проверьте, низкое ли входное напряжение

Имеются препятствия для чиллера